PoolWarden Training

There will be training for PoolWarden operation on Wednesday, January 11 2017. Location: SCP San Juan Capistrano 11-1 pm  

Continue Reading →

BUSTING WATER MAINTENANCE MYTHS

Here is a good article about water testing and water quality for swimming pools and spas. CLICK HERE

Continue Reading →

Bay Area Swimming Pool Information Committee

Presentation yesterday for Title 22 swimming pool automated data compliance at Contra Costa Environmental Health for the Bay Area Swimming Pool Information Committee. Thanks to Lino Ancheta, Roberto Rodriquez and Dave Hays from Dave’s Pool Service. The presentation can be downloaded HERE health presentation

Continue Reading →

Aquatics International- Cyanuric Acid:Good or Bad?

From Aquatics International. A short, worthwhile read about the use of cyanuric acid HERE

Continue Reading →

Why Pool Heaters Fail

The question came up as to why pool heaters fail. This is not a simple question to answer as there are several causes for this and it can be just one or a combination of things which will damage a pool heater. Older pool heater were more forgiving but the new low NOX, high efficiency…

Continue Reading →

Title 22 – PoolWarden Training Opportunity

On Wednesday, December 12, 2016 Superior Pool Products Ontario will be hosting a training on how the PoolWarden will bring you into compliance with the Title 22 daily record requirement. It will go from 11-1 and lunch will be provided. For more info contact. Anthony Flores customer Service Supervisor at 909.923.3600 or email anthony.flores@poolcorp.com. Address is :…

Continue Reading →

ORP Setpoints

It is not uncommon for users of ORP controllers to be uncertain how to determine ORP set points. Here is a simple way of determining where to start. Check chlorine, pH, alkalinity and cyanuric acid levels and adjust to desired levels. When your water is at the level you want and note the ORP reading…

Continue Reading →

Spa Alkalinity Control

Many people experience issues with spa alkalinity going low due to aeration and automated acid feed. Here is how to solve the problem of low total alkalinity. Depending on water volume and acid concentration use the following Set Points and relay on/off times. On If pH>7.6 or 7.7 On Time: 00:00:06 up to 00:00:08 MinTimeOff:00:00:45…

Continue Reading →

Title 22 Presentation

We were just invited to bring awareness of our Title 22 systems to the bay area environmental health jurisdictions on December 7, 2016 at the Contra Costa Environmental Heath office in Concord, CA. The goal is to achieve continuity between counties and demonstrate how our systems collect and record the required data for Title 22 swimming…

Continue Reading →

Quick Reference Stickers Now Available

Working to enhance our customer’s experience, we just released handy, quick reference stickers that can be placed on the back board next to the controller or anywhere else you would like. Stickers are available for the MiniWarden and PoolWarden. These labels can be used outdoors. Contact Lance at 530.205.4520 x105 or lance@controlomatic.com if you would…

Continue Reading →